  • General:
    • Is running on MS Windows 7, 8.1, 10, Windows Server 2012, Windows Server 2012 R2 and Windows Server 2016. (With CPTT 2.18.1 MS Windows XP and Vista are not supported anymore.)
      • New: Tested with MS Windows 10 version 1809 (October 2018 Update).
    • (2.18.2) Issue with network monitoring (if Pcap is not used) fixed: network adapter with many IP addresses are not ignored anymore.
    • (2.18.2) User Engine Class V1-API and User Engine Class V2-API marked as deprecated, will be removed in 2019.
    • (2.18.4) RIO Client improved for CPLB Design pattern "Frame Scanner NGT 2018".
    • Many minor improvements ...

  • GUI:
    • General Preferences: New items "Max. Stationname width" and "Max. DataObj name width": If Formatting option "Names" is selected and names are shown instead of addresses, then these items are used to determine the maximum name width.
    •  Drag&Drop ] implemented for MLG and MLS files:
      • Drag an MLG file to the Message View and drop the file: File will be read.
      • Drag an MLS file to the Message List Storage window and drop the file: File will be read.
    • For Message List Storage windows and Message List window, menus and background menus (right mouse button menu) were reworked.
    • Fixed: Message List Single Step: If for a Message List "Number of cycles" wasn't 0 (endless), Single Step did not wait for user action.
    • (2.18.2) CPTT splash window reworked: New button "Cancel" stops the search for a license.
    • (2.18.2) With serial line-based protocols: When monitoring serial line communication, in the main window footer now the modem signals CTS, DSR, DCD, RI of "Serial Comm. Port A" are shown, the modem signals of "Serial Comm. port B" are ignored (before the modem signals of port A and port B are shown alternatingly, this was never useful).
    • (2.18.3) New keyboard shortcut in Message View window: ALT+CTRL+z clears Message Storage/View.
    • (2.18.3) New actions when in Message View window SHIFT or CTRL is pressed while mouse wheel is scrolled:
      • SHIFT+mouse wheel scrolls horizontally to left resp. right.
      • CTRL+mouse wheel decreases or increases the Message View font size.
    • (2.18.3) The size of some windows are adapted.
    • (2.18.4) Reading and processing of an MLG file got a significant speed boost, files with more than 1,000,000 items will now be shown within seconds.
    • (2.18.4) Changing of Formatting options got a speed up, Link Layer or verbose Message display is now on the screen within seconds.
    • (2.18.4) Fixed: "Extra, Create Message List" is now working as expected.
    • Many minor improvements ...

  • Transmission Protocols:
    • (2.18.2) IEC 60870-5-101/-104: Message View Filter for Messages described in IEC 60870-5-7 resp. IEC 62351-5 implemented.
    • (2.18.2) IEC 60870-5-101 balanced: Message Coloring is now based on whether Controlling or Controlled Station is simulated. IEC 60870-5-101 file transfer now runs correctly regardless of Direction bit, confusing coloring is fixed.
    • (2.18.2) IEC 60870-5-104: Moved to CPLB Design pattern "Frame Scanner NGT 2018".
    • (2.18.3) IEC 60870-5-104: Experimental: IEC 62351-3: TLS-secured TCP/IP connections for server simulation implemented.
    • (2.18.4) IEC 60870-5-104: Experimental: IEC 62351-3: TLS-secured TCP/IP connections for client and server simulation implemented, demo certificate RealThoughts-Demo.cer with RealThoughts-Demo.key is part of installation.
    • DNP3 serial and DNP3 over LAN/WAN: All Messages described in DNP3 Secure Authentication resp. IEC 62351-5 are parsed and dissected: Functionscode 32, 33, 131, g120v1 ... g120v15, g121v1, g122v1, g122v2.
    • (2.18.2) DNP3 serial and DNP3 over LAN/WAN: Message View Filter for Functioncodes descibed in DNP3 Secure Authentication resp. IEC 62351-5 implemented.
    • (2.18.4) DNP3 serial and DNP3 over LAN/WAN: Moved to CPLB Design pattern "Frame Scanner NGT 2018".
    • (2.18.4) DNP3 over LAN/WAN: Experimental: IEC 62351-3: TLS-secured TCP/IP connections for client and server simulation implemented, demo certificate RealThoughts-Demo.cer with RealThoughts-Demo.key is part of installation.
    • (2.18.2) "Raw data serial" and "Raw data net": Protocols renamed.
    • (2.18.4) "Raw data serial" and "Raw data net": Moved to CPLB Design pattern "Frame Scanner NGT 2018".
    • (2.18.4) "Raw data serial" and "Raw data net": Experimental: TLS-secured TCP/IP connections for client and server simulation implemented, demo certificate RealThoughts-Demo.cer with RealThoughts-Demo.key is part of installation.
    • Many minor improvements ...